{"product_id":"ydq-10kva-100kv-gas-insulated-test-transformer","title":"YDQ-10kVA\/100kV Gas-Insulated Test Transformer","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eThe YDQ-10kVA\/100kV gas-insulated test transformer is primarily designed for high-voltage testing of power equipment rated at 35kV and below. Although capable of an output voltage of 100kV, practical applications must adhere to industry standards regarding test voltage multipliers; it is suitable for insulation testing of small to medium-sized power equipment, including:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e①\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eDistribution equipment: 10kV and 35kV distribution transformers.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e②\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSwitchgear and bushings: Circuit breaker arc-extinguishing chambers, vacuum interrupters, high-voltage porcelain insulators, and bushings.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e③\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eInsulated tools: Withstand voltage testing for high-voltage protective gear such as insulating rods, gloves, and boots.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e④\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eCable accessories: Terminations and joints for power cables rated at 35kV and below.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eThe equipment is mainly used to verify the insulation strength of the aforementioned devices, specifically through:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e①\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003ePower-frequency withstand voltage test: The primary application, used to assess insulation strength under power-frequency AC voltage.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e②\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eLeakage current test: Conducted in conjunction with a DC generator (requiring a rectifier unit) or as a basic AC leakage test.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e③\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecialized type tests: Used for educational experiments, material insulation breakdown testing, or fundamental laboratory research.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eUtilizing SF6 gas as the insulating medium, this series offers advantages such as compact size, light weight, and immunity to environmental and climatic conditions, making it particularly well-suited for field operations and routine maintenance at substations.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eTransformer\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e① Capacity: 10 kVA\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e② Input voltage: 0–200 V\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e③ Input current: 50 A\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e④ Output voltage: 0–100 kV\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e⑤ Output current: 100 mA\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e⑥ Metering voltage: 100 V\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eControl Console\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e① Capacity: 10 kVA\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e② Input voltage: AC 380 V\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e③ Output voltage: AC 0–250 V (continuously adjustable)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e④ Output current: AC 50 A\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e⑤ Structure: Benchtop or cabinet type available\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"musenelectric.com","offers":[{"title":"Default Title","offer_id":52358243156251,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/0967\/6315\/files\/10-100.jpg?v=1781580944","url":"https:\/\/musenelectric.com\/products\/ydq-10kva-100kv-gas-insulated-test-transformer","provider":"musenelectric.com","version":"1.0","type":"link"}