{"product_id":"six-cup-fully-automatic-oil-acid-value-tester","title":"Six-Cup Fully Automatic Oil Acid Value Tester","description":"\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eThis fully automatic acid value tester is a high-precision, fully digital industrial instrument meticulously developed by our company's R\u0026amp;D team through long-term, dedicated effort. It features a user-friendly design and an elegant appearance. Utilizing fully automatic digital microcomputer control based on the principle of acid-base neutralization, and incorporating proprietary algorithms for background blank subtraction and titration endpoint determination, the instrument delivers excellent measurement precision and accuracy.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eTesting the acid value of transformer and turbine oils is a routine procedure for oil-filled electrical equipment in power systems and industrial enterprises; this tester is a specialized device developed by our company specifically for this purpose. Built around a single-chip microcomputer, the instrument integrates technologies from optics, mechanics, electronics, and chemistry. It effectively replaces manual operations, thereby increasing efficiency, reducing operator workload, and minimizing exposure to harmful chemicals such as organic solvents.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eProduct Features:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e①\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eBased on the neutralization method, this tester uses microcomputer control to automatically perform liquid dispensing, stirring, titration, and endpoint determination at ambient temperature.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e②\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eA touchscreen LCD allows for the selection of all operating parameters; the interface is intuitive and user-friendly, ensuring ease of operation, with an average analysis cycle of approximately 2 minutes per oil sample.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e③\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eIt can store and display up to 35 sets of test results and print out various parameters related to the measurements.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e④\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecially designed reagent bottles are used to hold the extraction and neutralization solutions.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e⑤\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eReagents are stored in glass containers to prevent contamination from plastic additives.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e⑥\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eOperators do not need to come into contact with organic solvents during the testing process, minimizing health risks associated with chemical exposure.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e⑦\u003c\/span\u003e\u003cspan style=\"font-family: 黑体;\"\u003e　\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003eDepending on user requirements, the instrument can be configured to test between 1 and 6 samples. Product Specifications:\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1. Linear range: 0.001–0.400 mgKOH\/g\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e2. Correlation coefficient: 0.999–0.9998\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e3. Recovery rate: 98–103%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e4. Minimum resolution: 0.001 mgKOH\/g\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e5. Repeatability: 2%–5% (RSD)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e6. Measurement accuracy:\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFor acid values between 0.001 and 0.100 mgKOH\/g: ± 0.003 mgKOH\/g;\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFor acid values between 0.100 and 0.400 mgKOH\/g: 2%–5% of the indicated value;\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e7. Display: Large-screen color touch LCD (full Chinese character display)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e8. Dimensions: (L) 430 mm × (W) 370 mm × (H) 190 mm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e9. Net weight: ~9 kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eOperating Conditions\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e1. Ambient temperature: 0–40°C\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e2. Relative humidity: ≤ 85%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e3. Power supply: AC 220V ± 10%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e4. Power frequency: 50 ± 5 Hz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e5. Power consumption: \u0026lt;150 W\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"musenelectric.com","offers":[{"title":"Default Title","offer_id":52632903287067,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/0967\/6315\/files\/MSZ-2005-02.jpg?v=1784600722","url":"https:\/\/musenelectric.com\/products\/six-cup-fully-automatic-oil-acid-value-tester","provider":"musenelectric.com","version":"1.0","type":"link"}