Roll over or click image to zoom in

tan Delta Test Kit

musen
In stock
$0.00
$0.00
customers are viewing this product

MS-101G3tan Delta Test Kit

1. Equipped with CVT self-excited testing function, allowing simultaneous measurement of capacitance and Tgδ of C1 and C2 with a single connection.

2. Equipped with reverse connection low-voltage shielding and high-voltage shielding functions, C11 can be used for 10kV reverse connection dielectric loss measurement when the CVT bus is grounded, without disconnecting the conductor.

3. Capable of applying external voltage and measuring Cn.

4. Equipped with CVT ratio measurement function, meeting the ratio measurement requirements of 35~500kV CVT devices.

5. Equipped with multi-channel synchronous measurement function, capable of simultaneously testing the dielectric loss values of four test samples.

6. Equipped with insulation resistance testing function, capable of performing polarization index, absorption rate, and insulation resistance tests.

7. Equipped with automatic LCR measurement function, capable of measuring inductance, capacitance, and resistance.

8. Employs frequency conversion technology to eliminate 50Hz power frequency interference in the field, ensuring reliable measurement data even in environments with strong electromagnetic interference.

9. Overcurrent protection function ensures that the instrument will not be damaged in the event of a short circuit or breakdown of the test sample.

10. Standard configuration includes capacitors and a high-voltage power supply, facilitating on-site testing and reducing on-site wiring.

11. The instrument features a large LCD screen for easy operation. Menu guidance guides the testing process.

12. A wiring diagram is provided below the instrument's function interface, greatly simplifying wiring for operators.

13. Supports switching between Chinese and English languages.

1. Operating Conditions: -15℃-40℃ RH<80%
2. Anti-interference Principle: Frequency conversion method
3. Power Supply: AC 220V±10%, generator compatible
4. High Voltage Output: 0.5KV -12KV, adjustable in 0.1kV increments
5. Accuracy: 2%
6. Maximum Current: 200mA
7. Capacity: 2000VA
8. Self-excitation Power Supply: AC 0V-50V 15A
9. Single Frequency: 45.0Hz-65.0Hz, arbitrarily adjustable
10. Dual Frequency:
45.0Hz 55.0Hz  47.5Hz 52.5Hz
55.0Hz 65.0Hz  57.5Hz 62.5Hz
11. Resolution: tgδ: 0.1%  Cx: 0.1pF
12. Accuracy: △tgδ: ±(reading*1.0%+0.040%), △Cx: ±(reading*1.0%+1pF)
13. Measurement Range: tgδ: No limit
Cx: 15pF < Cx < 300nF
10kV Cx=(Cx1+Cx2+Cx3+Cx4) < 60 nF
5kV Cx=(Cx1+Cx2+Cx3+Cx4) < 150 nF
1kV Cx=(Cx1+Cx2+Cx3+Cx4) < 300 nF
CVT test Cx=(Cx1+Cx2+Cx3+Cx4) < 300 nF

tan Delta Test Kit