Roll over or click image to zoom in

tan Delta Test Kit 101G3 (CVT Ratio + LCR + Insulation Resistance)

musen
In stock
$0.00
$0.00
customers are viewing this product

The Anti-Interference Automatic Dielectric Loss Tester employs variable-frequency power supply technology. By utilizing microcontrollers and advanced electronic circuitry, it achieves automatic frequency conversion, analog-to-digital conversion, and data processing, thereby delivering robust anti-interference capabilities, rapid testing speeds, high measurement accuracy, and user-friendly operation.

The variable-frequency power supply features a high-power switching power module, capable of outputting pure sine waves at single frequencies (45 Hz–65 Hz) as well as dual-frequency combinations (47.5 Hz/52.5 Hz, 45.0 Hz/55.0 Hz, 57.5 Hz/62.5 Hz, and 55.0 Hz/65.0 Hz). It performs automatic voltage boosting and automatically filters out 50 Hz power-frequency interference, making it ideally suited for on-site testing in environments with high electromagnetic interference, such as substations.

Key Features:

1.  **CVT Self-Excitation Testing:** Supports the self-excitation method for Capacitive Voltage Transformers (CVTs), allowing for simultaneous measurement of both C1 and C2 capacitance and dielectric loss (tgδ) with a single wiring setup.

2.  **Reverse Wiring Capabilities:** Features low-voltage shielding and high-voltage shielding functions for reverse wiring configurations; this enables dielectric loss measurements of the C11 section—using the 10 kV reverse wiring method—without the need to disconnect existing wiring, even when the CVT busbar is grounded.

3.  **External Voltage/Capacitor Measurement:** Supports measurement functions utilizing an externally applied voltage source or an externally connected standard capacitor (CN).

4.  **CVT Transformation Ratio Measurement:** Includes a function for measuring the transformation ratio of CVTs, meeting the requirements for CVT devices rated from 35 kV to 500 kV.

5.  **Multi-Channel Simultaneous Measurement:** Capable of simultaneously measuring the dielectric loss values of up to four test specimens.

6.  **Insulation Resistance Testing:** Features an insulation resistance testing mode, allowing for the measurement of Polarization Index (PI), Absorption Ratio (DAR), and insulation resistance values.

7.  **Automatic LCR Measurement:** Provides automatic measurement capabilities for inductance (L), capacitance (C), and resistance (R).

8.  **Variable-Frequency Anti-Interference:** Employs variable-frequency technology to effectively eliminate 50 Hz power-frequency interference present at the test site, ensuring reliable data acquisition even in environments with strong electromagnetic interference.

9.  **Overcurrent Protection:** Equipped with an overcurrent protection mechanism to prevent damage to the instrument in the event of a short circuit or dielectric breakdown of the test specimen.

10. **Integrated Standard Capacitor and HV Source:** Contains a built-in standard capacitor and high-voltage power supply, facilitating convenient on-site testing and minimizing the complexity of field wiring.

11. **Large-Screen LCD Interface:** Features an extra-large LCD screen for clear display and simple operation; the entire testing process is guided via intuitive Chinese-language menu prompts. 12. The instrument's functional interface features corresponding wiring diagrams, greatly facilitating the operator's wiring process.

13. Supports switching between Chinese and English languages.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Operating Conditions

-15℃∽40℃

RH80%

2

Anti-interference Principle

Variable Frequency Method

3

Power Supply

AC 220V±10%

Allow Generator

4

High-Voltage Output

 

 

 

0.5KV ∽12KV

Every 0.1 kV

Accuracy

2%

Maximum Current

200mA

Capacity

2000VA

5

Self-Oscillating Power Supply

AC 0V∽50V/15A

Single Frequency: 45.0 Hz – 65.0 Hz (Continuously Adjustable)

Dual Frequency:

45.0 Hz / 55.0 Hz   47.5 Hz / 52.5 Hz55.0HZ/65.0HZ   57.5HZ/62.5HZ

6

Resolution

tgδ: 0.001%

Cx: 0.001pF

7

Accuracy

 

tgδ: ±(Reading × 1.0% + 0.040%)

Cx: ±(Reading × 1.0% + 1.00 pF)

8

Measurement Range

tgδ

Unlimited

C x

15pF Cx 300nF

10kV

Cx=(Cx1+Cx2+Cx3+Cx4)60 nF

5kV

Cx=(Cx1+Cx2+Cx3+Cx4)150 nF

1kV

Cx=(Cx1+Cx2+Cx3+Cx4)300 nF

CVT Testing

Cx=(Cx1+Cx2+Cx3+Cx4)300 nF

9

Insulation Resistance

 

DC High Voltage: 0.510 kV     Accuracy: ± (2% of reading + 10 V)

Measurement Range: 0.1 MΩ – 1000 GΩ     

Measurement Error: 5% of reading + 0.1 MΩ

10

LCR Measurement Range

Inductance L > 20 H (2 kV)

Resistance R > 10 kΩ (2 kV)

LCR Measurement Accuracy

1%

Angular Resolution

0.01

11

CVT Ratio Range

10∽10000

CVT Ratio Accuracy

1%

CVT Ratio Resolution

0.01

12

Memory Capacity

Supports USB flash drive data storage

13

Weight (Main Unit)

25.75kg

Weight (Accessory Case)

33.44kg

 

tan Delta Test Kit 101G3 (CVT Ratio + LCR + Insulation Resistance)
You have successfully subscribed!