• Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions?

    0 Comments /
    Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions?
    Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions? Test Precautions for Partial Discharge-Free Gas-Insulated Test Transformers: I. Core Pre-Test Inspections 1. Confirm Gas Pressure: Check if the pressure of the insulating gas such as SF6 or N₂ inside the transformer is within the rated range. Low pressure will directly lead to a decrease in insulation strength, easily causing internal discharge or breakdown. 2. Ensure Sealing: Observe whether the pressure gauge reading is stable and confirm that there is no gas leakage. Poor sealing will cause the pressure to drop slowly, affecting the stability...
  • GIS Partial Discharge Withstand Voltage Acceptance Test / GIS Withstand Voltage Test Equipment - Test Precautions?

    0 Comments /
    GIS Partial Discharge Withstand Voltage Acceptance Test / GIS Withstand Voltage Test Equipment - Test Precautions?
    GIS Partial Discharge Withstand Voltage Acceptance Test / GIS Withstand Voltage Test Equipment - Test Precautions? GIS Partial Discharge Withstand Voltage Acceptance Test / GIS Withstand Voltage Test Equipment - Test Precautions? The GIS withstand voltage test is a crucial step in verifying its insulation performance, and its operation requires meticulous attention. The following are the main precautions: I. Pre-Test Safety Confirmation 1. Complete Isolation: Ensure complete isolation of the GIS from all possible power sources. Connect grounding wires and set up safety barriers and warning signs. 2. Internal Cleanliness and Dryness: Confirm that the SF6...
  • High Voltage Resonance Test System for GIS - Test Precautions?

    0 Comments /
    High Voltage Resonance Test System for GIS - Test Precautions?
    AC High Voltage Test Apparatus/High Voltage Resonance Test System for GIS - Test Precautions?  The test precautions for the high voltage resonance test system are as follows: I. Precise Preparation Before the Test 1. Parameter Matching Calculation: Accurately estimate or measure the capacitance of the test sample and calculate the expected resonant frequency. Configure reactor combinations and taps reasonably according to the equipment's rated parameters (voltage, current, capacity) to ensure the system resonant point falls within the operating range. 2. System Inspection and Grounding: Thoroughly inspect the excitation transformer, reactors, voltage dividers, and high-voltage connection components...