• Oil-Immersed Partial Discharge-Free High Voltage Test Device - Test Precautions?

    0 Comments /
    Oil-Immersed Partial Discharge-Free High Voltage Test Device - Test Precautions?
    Partial Discharge-Free Power Frequency AC High Voltage Test System/Oil-Immersed Partial Discharge-Free High Voltage Test Device - Test Precautions? The following are the test precautions for the oil-immersed partial discharge-free high voltage test device: I. Detailed Preparation Before the Test 1. Check Oil Level and Quality: Confirm that the transformer oil level is within the standard range, the oil is transparent, and there are no carbon deposits or suspended matter. If the oil quality is deteriorated or the electrical strength is unqualified, it needs to be replaced or filtered. 2. Reliable Grounding: The device casing and grounding...
  • Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions?

    0 Comments /
    Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions?
    Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions? Core Test Precautions for Partial Discharge-Free Gas-Insulated Test Transformers: I. Core Pre-Test Inspections 1. Confirm Gas Pressure: The primary inspection item is the pressure of the insulating gas such as SF₆ or N₂ inside the transformer. It must be strictly maintained within the manufacturer's specified rated value range. Insufficient pressure will directly lead to a decrease in insulation strength, potentially causing internal discharge or breakdown. 2. Ensure Sealing: Observe whether the pressure gauge reading is stable and confirm that there are no signs of gas...
  • Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions?

    0 Comments /
    Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions?
    Partial Discharge-Free Test Transformer/Partial Discharge-Free Gas-Insulated Test Transformer - Test Precautions? Test Precautions for Partial Discharge-Free Gas-Insulated Test Transformers: I. Core Pre-Test Inspections 1. Confirm Gas Pressure: Check if the pressure of the insulating gas such as SF6 or N₂ inside the transformer is within the rated range. Low pressure will directly lead to a decrease in insulation strength, easily causing internal discharge or breakdown. 2. Ensure Sealing: Observe whether the pressure gauge reading is stable and confirm that there is no gas leakage. Poor sealing will cause the pressure to drop slowly, affecting the stability...